Top
One stop solutions for Submersible Pump Cables

Rubber H07RN-F Submersible Pump Cables

Construction

Conductor

High purity electrolytic grade bright annealed flexible bunched bare, copper conductor according to international standards like IS 8130, BS 6360, IEC 228 & VDE 0295.

Insulation

Oil & water resistant EI4 quality Elastomeric rubber.

Sheath

Tough & flexible EM2 quality Elastomeric rubber.

Standards

CENELEC HD 22.1.S2, BS 6007, DIN VDE 0282 Part 810, IEC 60245, CEI 20-19

Working Voltage Uo/U

450/ 750 V

Test Voltage

3000 V

Temperature range

-400C to 900C

Core colors (For Asian, African Markets) (For European Markets)
3 core Red ,Yellow, Blue Black, Blue, Brown
4 core Red ,Yellow, Blue, Green Black, Blue, Brown, Green
Sheath color: Choice of Black or Blue Choice of Black or Blue

3 CORE ROUND

Number of cores x cross-section
no of core x mm2
Mean insulation thickness
mm
Outside diameter min.
mm
Outside diameter max.
mm
Max cond. resistance
mm
3 G 1.5 0.8 9.6 12.5 12.1
3 G 2.5 0.9 11.5 14.5 7.41
3 G 4 1 13 16 4.95
3 G 6 1 14.5 20 3.3
3 G 10 1.2 20 25.5 19.1
3 G 16 1.2 22.5 29.5 1.21
3 G 25 1.4 26.5 34 0.78
3 G 35 1.4 29.5 38 0.554
3 G 50 1.6 34.5 44 0.386
3 G 70 1.6 39 49.5 0.272
3 G 95 1.8 44 54 0.206
3 G 120 1.8 47.5 50 0.161
3 G 150 2 52.5 66.5 0.129
3 G 185 2.2 58 71.5 0.106
3 G 240 2.4 65.5 81 0.0801
3 G 300 2.6 72.5 89.5 0.0641

4 CORE ROUND

Number of cores x cross-section
no of core x mm2
Mean insulation thickness
mm
Outside diameter min.
mm
Outside diameter max.
mm
Max cond. resistance
mm
4 G 1.5 0.8 10.5 13.5 12.1
4 G 2.5 0.9 12.5 15.5 7.41
4 G 4 1 14.5 18 4.95
4 G 6 1 16.5 22 3.3
4 G 10 1.2 21.5 28 19.1
4 G 16 1.2 24.5 32 1.21
4 G 25 1.4 29.5 37.5 0.78
4 G 35 1.4 33 42 0.554
4 G 50 1.6 38 48.5 0.386
4 G 70 1.6 43 54.5 0.272
4 G 95 1.8 49 60.5 0.206
4 G 120 1.8 53 65.5 0.161
4 G 150 2 58.5 74 0.129
4 G 185 2.2 64.5 79.5 0.106
4 G 240 2.4 73 90 0.0801

Note:

Insulation thickness, Sheath thickness and overall dimensions are nominal values. The number of wires is approximate and strand diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance as per IS 8130/1984, BS-6360, IEC-228 & VDE-0295.